Что делать? |
No. | Description | Remarks |
511 | Sets the copying start temperature for auto start mode. |
0: 140°C (standard)
1: 180°C |
512 | Sets the copying start temperature. |
0: 160°C (standard)
1: 180°C |
513 |
Sets the fixing target temperature for A3, A4,
279 x 432mm (11" x 17"), LTR. |
0: Standard target temperature
1: Standard target temperature +10°C 2: Standard target temperature + 5°C 3: Standard target temperature - 5°C 4: Standard target temperature -10°C |
514 | Sets the fixing target temperature for B4, B5, and LGL. |
0: Standard target temperature
1: Standard target temperature +10°C 2: Standard target temperature + 5°C 3: Standard target temperature - 5°C 4: Standard target temperature -10°C |
515 |
Sets the fixing target temperature for A4R, A5,
B5R, and LTRR. |
0: Standard target temperature
1: Standard target temperature +10°C 2: Standard target temperature + 5°C 3: Standard target temperature - 5°C 4: Standard target temperature -10°C |
516 | Sets the fixing target temperature for A5R. |
0: Standard target temperature
1: Standard target temperature +10°C 2: Standard target temperature + 5°C 3: Standard target temperature - 5°C 4: Standard target temperature -10°C |
![]() |
|
2007-2013 |